Fechar

1. Identificação
Tipo de ReferênciaArtigo em Revista Científica (Journal Article)
Siteplutao.sid.inpe.br
Código do Detentorisadg {BR SPINPE} ibi 8JMKD3MGPCW/3DT298S
IdentificadorJ8LNKAN8RW/3C647SL
Repositóriodpi.inpe.br/plutao/2012/06.21.21.30   (acesso restrito)
Última Atualização2012:08.29.14.16.01 (UTC) administrator
Repositório de Metadadosdpi.inpe.br/plutao/2012/06.21.21.30.43
Última Atualização dos Metadados2021:01.02.03.52.40 (UTC) administrator
DOI10.1007/s00703-012-0182-z
ISSN0177-7971
Rótulolattes: 4336175279058172 2 MesingerCGJBBLLMRV:2012:UpVeEt
Chave de CitaçãoMesingerCGJBBLLMRV:2012:UpVeEt
TítuloAn upgraded version of the Eta model
Ano2012
MêsMay
Data de Acesso26 abr. 2024
Tipo SecundárioPRE PI
Número de Arquivos1
Tamanho1197 KiB
2. Contextualização
Autor 1 Mesinger, Fedor
 2 Chan, Chou Sin
 3 Gomes, Jorge L.
 4 Jovic, Dusan
 5 Bastos, Paulo
 6 Bustamante, Josiane F.
 7 Lazic, Lazar
 8 Lyra, André A.
 9 Morelli, Sandra
10 Ristic, Ivan
11 Veljovic, Katarina
Identificador de Curriculo 1
 2 8JMKD3MGP5W/3C9JGRQ
Grupo 1
 2 DMD-CPT-INPE-MCTI-GOV-BR
 3 CPT-CPT-INPE-MCTI-GOV-BR
 4
 5
 6 CPT-CPT-INPE-MCTI-GOV-BR
 7
 8 CPT-CPT-INPE-MCTI-GOV-BR
Afiliação 1 Univ Maryland, ESSIC, College Pk, MD 20742 USA
 2 Instituto Nacional de Pesquisas Espaciais (INPE)
 3 Instituto Nacional de Pesquisas Espaciais (INPE)
 4 NCEP Environm Modeling Ctr, Camp Springs, MD USA
 5 Brazilian AF, Brasilia, DF, Brazil
 6 Instituto Nacional de Pesquisas Espaciais (INPE)
 7 Univ Belgrade, Inst Meteorol, Belgrade, Serbia
 8 Instituto Nacional de Pesquisas Espaciais (INPE)
 9 Univ Modena & Reggio Emilia, Dept Phys, Modena, Italy
10 Weather2Umbrella Co, Belgrade, Serbia
11 Univ Belgrade, Inst Meteorol, Belgrade, Serbia
Endereço de e-Mail do Autor 1 fedor@essic.umd.edu
 2 chou@pesquisador.cnpq.br
Endereço de e-Mailchou@pesquisador.cnpq.br
RevistaMeteorology and Atmospheric Physics
Volume116
Número3-4
Páginas63-79
Nota SecundáriaB1_GEOCIÊNCIAS B1_INTERDISCIPLINAR
Histórico (UTC)2012-06-22 00:11:01 :: lattes -> administrator :: 2012
2012-07-17 13:05:03 :: administrator -> secretaria.cpa@dir.inpe.br :: 2012
2012-08-29 14:16:01 :: secretaria.cpa@dir.inpe.br -> administrator :: 2012
2021-01-02 03:52:40 :: administrator -> marciana :: 2012
3. Conteúdo e estrutura
É a matriz ou uma cópia?é a matriz
Estágio do Conteúdoconcluido
Transferível1
Tipo do ConteúdoExternal Contribution
Tipo de Versãopublisher
Palavras-Chavepressure-gradient force
volume integration method
step-mountain coordinate
convective parameterization
single-column
scheme
precipitation
atmosphere
advection
impact
ResumoUpgrades implemented over a number of years in an open source version of the Eta model, posted at the CPTEC web site http://www.emc.ncep.noaa.gov/mmb/wrkstn_eta, which differs from the NCEP's latest operational Eta by having the WRF-NMM nonhydrostatic option included. Most of the upgrades made resulted from attention paid to less than satisfactory performance noted in several Eta results, and identification of the reasons for the problem. Others came from simple expectation that including a feature that is physically justified but is missing in the code should help. The most notable of the upgrades are the introduction of the so-called sloping steps, or discretized shaved cells topography; piecewise-linear finite-volume vertical advection of dynamic variables; vapor and hydrometeor loading in the hydrostatic equation, and changes aimed at refining the convection schemes available in the Eta. Several other modifications have to do with the calculation of exchange coefficients, conservation in the vertical diffusion, and diagnostic calculation of 10-m winds. Several examples showing improved performance resulting from the dynamics changes are given. One includes a case of unrealistically low temperatures in several mountain basins generated by a centered vertical advection difference scheme's unphysical advection from below ground, removed by its replacement with a finite-volume scheme. Another is that of increased katabatic winds in the Terra Nova Bay Antarctica region. Successful forecast of the severe downslope zonda wind case in the lee of the highest peaks of the Andes is also shown, and some of the recent successful verification results of the use of the upgraded model are pointed out. The code is used at numerous places, and along with setup information it is available for outside users at the CPTEC Eta web site given above.
ÁreaMET
Arranjourlib.net > BDMCI > Fonds > Produção anterior à 2021 > DIDMD > An upgraded version...
Conteúdo da Pasta docacessar
Conteúdo da Pasta sourcenão têm arquivos
Conteúdo da Pasta agreementnão têm arquivos
4. Condições de acesso e uso
Idiomaen
Arquivo AlvoMesinger_et_al_2012.pdf
Grupo de Usuáriosadministrator
lattes
secretaria.cpa@dir.inpe.br
Visibilidadeshown
Política de Arquivamentodenypublisher denyfinaldraft12
Permissão de Leituradeny from all and allow from 150.163
Permissão de Atualizaçãonão transferida
5. Fontes relacionadas
Unidades Imediatamente Superiores8JMKD3MGPCW/3EUPEJL
8JMKD3MGPCW/43SKC35
DivulgaçãoWEBSCI; PORTALCAPES; COMPENDEX.
Acervo Hospedeirodpi.inpe.br/plutao@80/2008/08.19.15.01
6. Notas
NotasSetores de Atividade: Pesquisa e desenvolvimento científico.
Campos Vaziosalternatejournal archivist callnumber copyholder copyright creatorhistory descriptionlevel format isbn lineage mark mirrorrepository nextedition orcid parameterlist parentrepositories previousedition previouslowerunit progress project readergroup rightsholder schedulinginformation secondarydate secondarykey session shorttitle sponsor subject tertiarymark tertiarytype typeofwork url
7. Controle da descrição
e-Mail (login)marciana
atualizar 


Fechar